LC-9210II NEXT and LC-9260II NEXT

  • All in one body - Smart and compact ! 
  • Manual operation Model

LC-9110NEXT LC-9130NEXTLC-9110II NEXT LC-9260II NEXT

1/3 Body size compared to our previous model.

Product Features

  • With non-Diffusion function Recycling system (Patented) - During extended recycling period, the recycled sample in the flow line may diffuse back into the solvent with the danger of contaminating the solvent reservoir. The NEXT series has non-diffusion device (patent) that prevents the sample from running back into the solvent line and also damaging your columns and detectors with back pressure.
  • Auto cleanup function - Keeps the flow channels clean automatically. Solvent changeover when changing columns is also made much easier.
  • Pumps depend on column sizes - LC-9210 NEXT Maximum flow rate: 10.0mL/min, LC-9225 NEXT Maximum flow rate: 25.0mL/min. Please select a model with your column size.
  • Improved layout - Manual injector is mounted outside of the body. Maintenance such as seal exchange becomes greatly easy. The pump and the detectors are also easily taken out by opening the front panel.
  • Easy setup on the panel - The sheet switch panel has all necessary operational functions such as start the pump, set up the flow rate and detectors, recycling and collecting as well as auto cleanup.
  • Auto calculation for right fraction timing - The time difference between detection and actual fraction will be automatically calculated and programmed.
  • Maximum flow rate -model 9210II NEXT is 10mL/min, model 9260II NEXT is 60mL/min

 

JAI 9210 9260 flow channel chart

LC NEXT flow channel chart

Detector

Two different types of detectors small enough to fit into NEXT series body have been developed. They can be installed together and perform detection simultaneously. 

  • UV Detector - As preparative dedicated detector, it has developed its stability and sensitivity can detect most organic compounds
      UV-254II NEXT UV-370 NEXT UV-600 NEXT UV-VIS 4ch NEXT
    Detection single fixed wavelength single variable wavelength single variable wavelength 4-channel variable wavelength
    Wave length 254mm 195-370mm 195-600mm 190-480mm
    Measurement Method Signle beam filter Double beam Double beam Single beam
    Flow Cell
    Cell Length: 0.3mm, Cell volume: 40µl (Option: 1.0mm, 2.4mm)
    Cell Length: 0.5mm, Cell vol: 20µl (Option: 0.2mm, 0.1mm)
    Cell Length: 0.5mm, Cell vol: 20µl (Option: 0.2mm, 0.1mm)
    Cell Length: 0.3mm, Cell vol: 40µl (Option: 1.0mm, 2.4mm)

 

  • RI Detector - Stable baseline can be obtained quickly. Applicable for both preparative and analytical HPLC
  RI-700NEXT
Measurement Method
Deflection
Flow Cell
8µl volume
RI Range
1.00-1.75
Attenuator
1-2000, ∞ in 12 steps

 

 
 